Creda NP150 75-772903 ユーザーズマニュアル

ページ / 4
Wattage (W) 
Model  with 
controls white 
Model with controls 
silver 
Model  with no 
controls white 
Dimensions 
(mm) 
500 
NPP50 75-773001 
NPP50S 75-773011 
NP50 75-772901 
442 x 430 x 80 
1000 
NPP100 75-773002 
NPP100S 75-773012 
NP100 75-772902 
680 x 430 x 80 
1500 
NPP150 75-773003 
NPP150S 75-773013 
NP150 75-772903 
680 x 430 x 80 
2000 
NPP200 75-773004 
NPP200S 75-773014 
NP200 75-772904 
852 x 430 x 80 
Creda Newera Profile and Profile Plus Panel Heaters 
Installation and Operating Instructions 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The Newera Profile panel heater range is designed for wall mounting on the wall brackets supplied.  It 
should only be operated when in the upright position as shown in diagram C. 
All models are protected against moisture ingress to IPX4 standard. 
All models, except those with no controls, are fitted with a 7-day digital programmer. 
Installation: 
Before connecting the heater, check that the supply voltage is the same as that stated on the rating label. 
When selecting the position for the heater to be installed, consideration should be given to ensure that there 
are no obstructions closer than the dimensions given in Diagram C.  The bracket for the heater should be 
fitted in accordance with the method detailed in the associated diagrams.  The heater must not be located 
below a socket outlet or connection box. 
Care must be exercised when fitting the heater onto the bracket.  Pressure should only be applied to 
the ends of the heater and not to the grille area. 
The electrical installation must be carried out by a competent electrician and in accordance with the current 
Electrical Wiring Regulations (BS7671) and/or local regulations. 
The heater is fitted with a length of flexible cable for connection to the fixed wiring of the premises via a 
suitable connection box positioned adjacent to the heater. 
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 
qualified persons in order to avoid a hazard. 
A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with 
the wiring rules. 
WARNING – THIS APPLIANCE MUST BE EARTHED 
WARNING – In order to avoid overheating, do not cover the heater.