Samsung AM27B1(B2)C13 ユーザーズマニュアル

ページ / 25
Technical Specifications
E-
24
✳ 
Standard rating conditions     Cooling
Indoor
DB
80
26.7
°F
°C
WB
67
19.4
DB
95
35.0
WB
75
23.9
Outdoor
10.0
10.0
MODEL
Performance
Ratings
Capacity Cooling
SEER
Moisture Removal
Air FLOW(Cooling, HIGH)
Sound Rating-Outdoor
Btu/h
Pts/h
CFM
dB
Electrical
Data
The number of operation
Power source
Min.Ampacity
Cooling Watts
A
W
Refrigeration
Lines
Indoor unit
Connections
Liquid Line O. D.
Suction Line O.D.
Factory Pre-charge
Max. Line length
Max. Height Difference
mm(in)
mm(in)
m(ft)
m(ft)
m(ft)
Dimensions
& Weight
W X H X D
Net Weight
mm(in)
Ibs
6.35 (1/4)
790 x 245 x 165
16
1
2  
)
(
17
132.3
17
152.1
7.0 (23)
7.0 (23)
9
1
2
31
1
8
x
x 6
1
2
880 x 638 x 310
)
(
25
1
8
34
1
2
x
x12
1
4
790 x 245 x 165
)
(
9
1
2
31
1
8
x
x 6
1
2
1000 x 790 x 310
)
(
31
1
8
39
1
2
x
x 12
1
4  
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Type
AM18B1(B2)C09 UM18B1(B2)C2 AM26B1(B2)C13 UM26B1(B2)C2
2 Comp + 2 Room
2 Comp + 2 Room
A/B-Unit : 9000
A/B-Unit : 12500
3
-
4
-
255
-
300
-
-
57
-
60
1 Unit operation 2 Unit operation 1 Unit operation 2 Unit operation
208-230V~,60Hz
208-230V~,60Hz
9.52 (3/8)
12.70 (1/2)
6.35 (1/4)
4.3
990
8.4
6.1
11.4
1920
1360
2550
A-Unit
B-Unit
A-Unit
B-Unit
Flare
Flare
5.0 (
)
16
1
2  
5.0 (
)
49
1
4  
15.0 (
)
49
1
4  
15.0 (
)