Chauvet ZX-30RG ユーザーズマニュアル

ページ / 5
Features
Removeable Head -To use the ZX-30RG as a projector, the head may be removed. In order to 
remove the head, simply unscrew the four screws holding the head bracket to the body of the unit 
and unplug the connecting cable.
Selectable Scanning Range - The ZX-30RG offers the user a choice of 3 scanning ranges (180, 150 
or 120 degrees). To select the desired scanning range, simply put the set screw in the hole marked 
with the range required.
Function - The ZX-30RG offers the user a choice of either static or scanning. This feature is con-
trolled by the 2 position switch on the bottom of the unit (located just above the fan). This controls 
only the scanning mirror. The gobo will always be rotating.
Color - The ZX-30RG comes complete with 4 dichroic glass filters (red, green, yellow and blue). To 
insert the filter, unscrew the filter holder on the bottom of the unit and slide the desired color into the 
holder. Replace the holder in the unit and screw in tightly.
Gobo - The ZX-30RG is supplied with 4 interchangeable gobos. To change/insert a gobo, remove 
the screw on the bottom of the unit securing the gobo holder. Remove the gobo and replace with the 
desired gobo. Replace the gobo holder in the ZX-30RG and secure the screw tightly. The ZX-30RG 
will accept custom gobos. The gobo has a diameter of 25 mm. The image area has a diameter of 
18mm.
Installation / Mounting
Although this unit can be used in an upright position, it is recommended that, for safety purposes, 
your lighting effect be properly mounted using a suitable hanging clamp and safety cable. CHAUVET 
offers a range of items, which are ideal for safe mounting. 
Replacing Lamps
1.  Disconnect from main power supply before attempting to replace either lamps or fuse. 
2.  Ensure that the unit is sufficiently cool, before removing blown lamps.
3.  Never touch new lamps with your fingers; use a tissue or a cloth. 
In order to replace the lamp, disconnect from main power supply first, and unscrew the lamp 
replacement cover, which is highlighted on the diagram (fig.1). Only use the appropriately rated 
lamps as use of any other lamp type may cause the unit to be non-operational.
Due to the nature of halogen lamps it is vitally important that you do not touch the new replacement 
lamp with your fingers, as this will reduce lamp life considerably. Once again a tissue or cloth can be 
used for fitting the replacement lamp.
Finally before using, check that the lamp is housed correctly in the lamp holder and that the lamp 
replacement cover has been screwed back into place.
If after replacement of the lamp, the unit is still not working then please contact CHAUVET
for servicing.