PROPERTY DAMAGE
System.has.hot.water.spray.that.must.be..
connected..Fresh.water.connection.to.the..
Waste.Xpress.must.be.hot.water.only..Failure..
to.use.hot.water.may.clog.system.and.result..
in.malfunction.
WASTE OUTLET LINE 
Connect.a.2".drain.line.to.the.Waste.Xpress.waste..
outlet.as.specified.per.local.codes.(see.Figure.18..
for.water.outlet.location).
InSinkErator.recommends.that.the.water.outlet..
empties.into.a.floor.drain.
If.the.water.outlet.connection.on.the.Waste.Xpress
needs.to.be.switched.to.the.other.side,.complete..
the.following:
•.Remove.the.four.screws.holding.the.cap.and.gasket.in.
position.(see.Figure.18).
•.Install.gasket,.cap.and.inlet.fitting.on.reverse.side..
and.secure.with.appropriate.screws.
NOTE: The Waste Xpress system should not be 
plumbed directly into a small inside grease trap.  
The unit can be plumbed through a large exterior  
grease trap.
WATER SUPPLY CONNECTIONS
When.connecting.the.incoming.water.supply.to.the
disposer,.sink.bowl.and.Waste.Xpress,.use.as.few
elbows.and.tees.as.possible.
All.cold.water.line.fittings.are.1/2".NPT.except.the
sink.bowl.nozzles.which.are.1/2".compression...
Use.1/2".compression.fitting.to.connect.hot.water..
to.Waste.Xpress.
Install.the.flow.control.valve,.water.solenoid.valve,
and.syphon.breaker.according.to.the.direction.of.the
arrows.marked.on.each.valve.body.
NOTE: In-line hot and cold shutoff valves are 
recommended close to the Waste Xpress system  
for ease of service.
ROUTING WATER FLOW
Connect.cold.water.only.to.disposer,.bowl,.or.trough.
Connect.hot.water.only.to.Waste.Xpress.for.hot.water
spray.nozzles.
In.a.trough.system,.route.all.water.flow.to.the.end.of
the.trough.to.flush.food.waste.
Figure 19. Typical Installation Diagram
PLUMBING CONNECTIONS
The.syphon.breaker.is.supplied.with.all.Waste.Xpress.
systems.(packed.separately).
Syphon.breaker.must.be.installed.above.the.sink.flood
plane.
per local plumbing codes..Check.direction.of.
water.flow.arrows.
The.solenoid.valve.is.supplied.with.a.24.V.coil.
•.The.flow.control.valve.regulates.all.cold.water.flowing
. into.the.disposer.and.Waste.Xpress..This.conserves..
. water.and.prevents.overloading.
Plumbing Connections
Flow Control Valve
Disposer
Sink Bowl
Syphon Breaker
Cold Water Solenoid
Hot Water Solenoid
Waste Xpress
Shut Off Valve
(supplied 
by others)
WX-101A Controller
10  max
(3.1 m max)
1-1/2" min
(38.1 mm
min)
1" min
(25.4 mm min)