Desa VTD-30NV-JHB ユーザーズマニュアル

ページ / 20
www.desatech.com
114370-02C
10
INSTALLATION
Continued 
PRESSURE TESTING APPLIANCE GAS 
CONNECTIONS
1.  Open equipment shutoff valve (see Figure 8, 
page 9).
2.  Open main gas valve located on or near gas 
meter for natural gas or open propane/LP 
supply tank valve.
3.  Make sure control knob of appliance is in the 
OFF position.
4.  Check all joints from equipment shutoff valve 
to gas control (see Figures 9 or 10, page 9). 
Apply noncorrosive leak detection fluid to all 
joints. Bubbles forming show a leak.
5.  Correct all leaks at once.
6.  Light appliance (see Operating Appliance). 
Check all other internal joints for leaks.
7.  Turn off appliance (see To Turn Off Gas to 
Appliance, page 11)..
OPERATINg APPLIANCE
FOR YOUR SAFETY 
READ BEFORE LIGHTING
 WARNING: Keep flue open 
when operating unit.
 WARNING: If you do not fol-
low  these  instructions  exactly, 
a  fire  or  explosion  may  result 
causing property damage, per-
sonal injury or loss of life.
A.  This appliance has a pilot which must be 
lighted by hand. When lighting the pilot, 
follow these instructions exactly.
B.  BEFORE LIGHTING smell all around the 
appliance area for gas. Be sure to smell next 
to the floor because some gas is heavier than 
air and will settle on the floor.
  WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use 
any phone in your building.
• Immediately call your gas supplier from 
a  neighbor’s  phone.  Follow  the  gas 
supplier’s instructions.
• If you cannot reach your gas supplier, call 
the fire department.
C.  Use only your hand to push in or turn the 
gas control knob. Never use tools. If the 
knob will not push in or turn by hand, don’t 
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted 
repair may result in a fire or explosion.
D.  Do not use this appliance if any part has 
been  under  water.  Immediately  call  a 
qualified service technician to inspect the 
appliance and to replace any part of the 
control system and any gas control which 
has been under water.
LIGHTING 
 INSTRUCTIONS
NOTICE:  During  initial  opera-
tion of new appliance, metallic 
components may emit an odor as 
paint and assembly compounds 
are  heated  and  cure.  Be  sure 
to provide adequate fresh air if 
odors are detected.
  WARNING:  Damper  handle 
will be hot if appliance has been 
running.
 CAUTION: A mild gas flash 
may occur within 10 seconds of 
normal shutdown of this appli-
ance. Remain clear of the hearth 
area for the entire shutdown pro-
cess to avoid possible injury.
1.  STOP!  Read  the  safety  information  in 
column 1.
2.  Make sure equipment shutoff valve is fully 
open.
3.  Set selector switch in the OFF position. 
4.  Press in and turn control knob clockwise  
 to the OFF position (see Figure 11, 
page 11).
  WARNING:  Burners  will 
come  on  automatically  within 
one  minute  when  the  selector 
switch is in the ON position after 
the pilot is lit.