HP 320 G6 505683-421 ユーザーズマニュアル

製品コード
505683-421
ページ / 50
HP 400W Factory Integrated Power Supply Kit
Part Number
515739-B21
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100
120
200
208
220
230
240
Maximum Rated Output Wattage
400
400
400
400
400
400
400
Nominal Input Current (A rms)
5.5
5.0
2.5
2.4
2.3
2.2
2.1
Max Rated Input Wattage Rating (Watts)
510
500
480
480
480
480
480
Max. Rated VA (Volt-Amp)
520
520
500
500
500
500
500
Efficiency (%) at Max. Rated Output Wattage
83.0
84.0
86.0
86.0
87.0
87.0
87.0
Power Factor
0.97
Leakage Current (mA)
0.75
0.75
0.85
0.90
0.95
0.95
1.00
Max. Inrush Current (A peak)
35
Max. Inrush Current duration (mS)
20
Maximum British Thermal Unit Rating (BTU-Hr)
1739
1705
1636
1636
1636
1636
1636
 
HP 365W Hot Plug Redundant Power Supply Kit with Backplane
Part Number
532092-B21
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100
120
200
208
220
230
240
Maximum Rated Output Wattage
320
320
360
360
360
360
360
Nominal Input Current (A rms)
4.15
3.41
2.23
2.16
2.03
1.94
1.86
Max Rated Input Wattage Rating (Watts)
412
406
445
445
444
443
443
Max. Rated VA (Volt-Amp)
413
407
447
447
446
446
445
Efficiency (%) at Max. Rated Output Wattage
77.4
78.5
80.5
80.6
80.7
80.8
81
Power Factor
0.99
Leakage Current (mA)
0.75
0.75
0.85
0.90
0.95
0.95
1.00
Max. Inrush Current (A peak)
35
Max. Inrush Current duration (mS)
20
Maximum British Thermal Unit Rating (BTU-Hr)
1354
1334
1462
1462
1459
1456
1456
 
NOTE: To review typical system power ratings use the Active Answers Power Advisor which is available via the online tool located at
URL: 
.
QuickSpecs
HP ProLiant DL320 Generation 6 (G6)
Power Specifications
DA - 13344   Worldwide — Version 59 — March 5, 2013
Page  46