Vulcan-Hart BVD36FP52(F,L)N-1 ユーザーズマニュアル

ページ / 40
Page 26
19400-3-0406
1.  Turn off the gas supply.
2.  Turn  off  the  electrical  supply  to  the  appliance  if  so 
equipped.
3.  Open or remove glass doors if applicable.
4.  Remove top louver and lower bottom louver.
5.  Remove logs from burner assembly.
VALVE CONVERSION
6.  Remove plastic cap from regulator fitting. Unscrew fitting 
using a 7/16" wrench. Turn fitting over so end of fitting marked 
"LPG" is visible. Tighten fitting (snug only). Replace plastic 
cap.
7.  Remove 1/4" screw from air shutter.
8.  Located to the right of electrodes is a burner hold-down tab. 
Using needle-nose pliers, bend burner hold-down tab off the 
main burner. 
9.  Remove main burner by pivoting main burner forward as you 
slide main burner from left to right. Be careful as you remove 
main  burner  in  order  to  protect  the  electrodes  from  being 
damaged.
10. Remove air shutter from orifice fitting.
11. Remove natural gas main burner orifice from orifice fitting.
12. Install propane/LP main burner orifice marked 1.35mm for 
BVD34FP50, marked 1.45 mm for BVD36FP52, or marked 
1.65mm for BVP42FP52.
  Important:  Failure to install the correct orifice will result in 
unit over-firing that could overheat the appliance and result 
in a fire.
13. Replace air shutter onto orifice fitting. Air shutter must be 
threaded and bottomed-out onto orifice fitting.
14. Replace main burner onto burner assembly. Place main burner 
beneath electrodes, slide main burner from right to left into 
burner location, and pivot main burner away from you and 
into air shutter.
15. Set air shutter opening as indicated by the chart below. Tighten 
air shutter in place with 1/4" screw from step 7.
16. Using  needle-nose pliers, bend burner hold-down tab over 
main burner.
17. Refer to log placement, pages 14 and 15 to place logs onto 
burner assembly.
18. Loosen screw and attach a manometer or pressure gauge to 
the outlet pressure tap of the control valve. 
19. Turn on the gas supply. Turn on the electrical supply to the 
appliance. Check for gas leaks using soap and water solution 
or leak detection solution. Bubbles indicate a leak that MUST 
be corrected. Do not use an open flame to test for gas leaks.
20. Check  the  air  shutter  opening.  See  chart  and  illustration 
below.
21. Relight the main burners and verify proper burner ignition and 
operation.
22. With  the  main  burner  burning,  read  the  pressure  on  the 
manometer  or  pressure  gauge. The  pressure  on  the  gauge 
should read between 9.8" and 10.2" w.c.
23. Turn off the gas supply. Turn off the electrical supply to the 
appliance. 
24. Remove the manometer or pressure gauge. Tighten the screw 
in the pressure tap.
25. Turn on the gas supply. Turn on the electrical supply to the 
appliance. 
26. Immediately  test  all  gas  line  connections  and  the  control 
valve for gas leaks using a soap and water solution or other 
gas detection solution. Bubbles indicate a leak that MUST be 
corrected. Do not use an open flame to test for gas leaks. 
27. Using a ball point pen, fill out the conversion label that is 
supplied with the conversion kit. Place the conversion label 
adjacent to the rating plate. 
28. Test operation of fireplace once again. Allow the fireplace to 
operate for at least 10 minutes and check flame coloration. 
Flames  on  rear  of  burner  should  be  yellow  without  any 
orange-colored tip. Minor adjustment of the air shutter may 
be necessary to "tune in" the proper flame color.
Model
AIR SHUTTER 
SETTINGS
BURNER ORIFICE
Opening "A"
Propane/LP Orifice
BVD34 5/16" (8mm)
1.35mm
BVD36 5/16" (8mm)
1.45mm
BVP42 Full Open
1.65mm
“A”
REGULATOR FITTING
NOTE: STAMPED WITH
GAS TYPE SET FOR USE
Maxitrol Valve Conversion
DIRECT IGNITION PROPANE/LP GAS CONVERSION