Jotul GF 100 DV II ユーザーズマニュアル

ページ / 32
20
GF 100 DV II Nordic QT
GF 200 DV II Lillehammer
Optional Wall Thermostat or
Remote Control
Use only a 750 millivolt DC two-wire circuit thermostat
with this appliance. The thermostat should be placed in
the same room as the heater, typically 5 feet off the
floor. Avoid drafty areas or any area that may affect the
accuracy of the thermostat.
The thermostat should be connected to the Nordic
QT using a minimum of 16 gauge wire with a maximum
length of 35 feet of wire.
Connect the two thermostat wire leads to the two
lower terminals on the terminal block located directly
to the right of the valve.  Do not overtighten the con-
nections.  IT IS NOT NECESSARY TO DISCONNECT ANY
OTHER WIRES. See Fig. 27.
For thermostatic operation, the On/Off/T-Stat
switch on the back of the stove must be in the T-stat
position, and the pilot light must be running, as it is the
power source for the thermostat.
At the thermostat, the two wires should be con-
nected to the two connection screws on the thermostat
base plate per the manufacturer’s instructions.
Remote Control
 When using a remote, the remote receiver should be
wired to the terminal block the same way the thermo-
stat would be. See the instructions above.
Follow the operating instructions included with the
Remote Control unit.
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING THE CONTROLS.  WIRING
ERRORS CAN CAUSE IMPROPER OR DANGEROUS
OPERATION.  ALWAYS VERIFY PROPER OPERA-
TION AFTER SERVICING THE APPLIANCE.
Log Set Installation
NOTE: Install the optional Brick Kit, if appropriate, before
installing the Log Set.  See page 30.
The Log Set and Ember Stones are packaged in foam
inside the firebox. These must be installed in the firebox
prior to burner operation. Wear gloves to prevent skin
irritation from the ceramic fibers.
Position the Rear Log assembly as shown in fig 28,
engaging the pins on the burner skirt with the adjacent
holes in the underside of the log.
Locate the Middle Log as shown in fig. 29.
Also included is a bag of ember stones that simulate
glowing coals when the burner is operating. These
should be spread thinly over the burner plate.
NOTE: Keep the ember stones 1/4” away from the
edge of the Burner Skirt.  All the embers do not have to
be used.
Figure 27.  Accessory wiring diagram.
Figure 28. Install Rear Log.
TERMINAL
BLOCK
VALVE
THERMOPILE
OPTIONAL
THERMOSTAT
or
REMOTE
CONTROL
TH
TP
TH
TP
ROCKER
SWITCH
ON
OFF
STAT
Figure 29. Middle Log and ember stones in place.
1/4”
6 mm
1/4”
6 mm
Pilot
Assembly