Electrolux EAS(C,E)24C2ASK(W,S,M) ユーザーズマニュアル

ページ / 28
Fixing the installation plate
Drilling the Hole
1.  Install the installation plate 
horizontally over the structural 
parts on the wall using the spaces 
indicated on the plate, as shown in 
the figure above.
2.  In the case of tiled, concrete or 
similar walls, create 5 mm-
diameter holes. Place anchorage 
supports for the appropriate 
assembly screws.
3.  If expansion screws are used, the 
holes must measure 11x20 or 
11x26, with a distance of 450 mm 
between each.
4.  Fix the installation plate to the wall.
1.  Determine the position of the hole 
for the pipe using the installation 
plate and drill the pipe hole (ø 
65mm) so that it is titled slightly 
downward.
2.  Always use a pipe cover with an 
opening when drilling a metal bar.
Placa de instalación
Fit the Installation Plate and drill holes 
in the wall according to the wall 
structure and corresponding mounting 
points on the installation plate 
(Dimensions are in “mm” unless 
otherwise stated).
Wall
Indoor unit
Outdoor unit
5
-7
m
m
Do not put the end
of drain hose into water.
Do not block
water flow
by a rise.
Connective pipe and drainage installation
Drainage
1.  Run the drain hose sloping 
downward. Do not install the drain 
hose as illustrated below.
2.  When connecting extension drain 
hose, insulate the connecting part 
of extension drain hose with a 
shield pipe, do not let the drain 
hose slack.
13 electrolux indoor unit installation
Connective pipe installation
1. For the left-hand and right-hand 
piping, remove the pipe cover from 
the side panel.
2. For the rear-right-hand and rear-left-
hand piping, install the piping as 
shown. Bend the connective pipe to 
be laid at 43mm height or less from 
the wall.
3. Fix the end of the connective pipe. 
Right back
piping
Pipe cover
(left)
Pipe
holder
Pipe cover
(right)
Right piping
Connective
pipe
Indoor unit
outline
4
3
m
m
 
indoor unit installation
 electrolux 14
Do not block
water flow
by a rise.
1. Pass the piping through the hole in 
the wall.
2. Put the upper claw at the back of the 
indoor unit on the upper hook of the 
installation plate, move the indoor 
unit from side to side to see that it is 
securely hooked (see Fig.10 & 
Fig.11).
Fastening the Indoor Unit 
Upper hook
Lower hook
150mm del techo
above 120mm
from the wall
998
2
9
3
above 120mm
from the wall
Indoor unit outline
5
0
130
Refrigerant pipe
hole (left)  Ø 65 
119
380
380
5
0
130
4
1
Modelos 24000 Btu’s