M ake sure the wiring is adequate for your unit.
If you have fuses, they should be of the time delay type.  Before you install 
or relocate this unit, be sure that the amperage rating of the circuit breaker 
or time delay fuse does not exceed the amp rating listed in Table 1.
DO NOT use an extension cord.
The cord provided will carry the proper amount of electrical power to the 
unit; an extension cord may not.
M ake sure that the receptacle is compatible with 
the air conditioner cord plug provided.
Proper grounding must be maintained at all times.  Two prong receptacles 
The grounded receptacle should meet all national and local codes and 
ordinances.  You must use the three prong plug furnished with the air 
conditioner.  Under no circumstances should you remove the ground 
prong from the plug.
Test the power cord
All Friedrich room air conditioners are shipped from the factory with a 
Leakage Current Detection Interrupter (LCDI) equipped power cord.  The 
LCDI device on the end of the cord meets the UL and NEC requirements 
for cord connected air conditioners.
To test your power supply cord:
1. 
Plug power supply cord into a grounded 3 prong outlet.
2. 
Press RESET (See Figure 1).
3. 
Press TEST, listen for click; the RESET button trips and pops out.
4. 
Press and release RESET (Listen for click; RESET button latches 
and remains in).  The power cord is ready for use.
WARN I NG: Before Operating Your Unit
MODEL
CIRCUIT RATING 
OR TIME DELAY 
FUSE
REQUIRED 
WALL 
RECEPTACLE
AMP
VOLT
NEMA 
NO.
SS08, SS10
SS12, SS14
YS10, SM15
15
125
5-15R
SS12,
 
SS15
SM18,
 
SM21
15
250
6-15R
SM24, SL28
ES12, ES15
YS12
20
250
6-20R
SL36, EM18
EM24, EL36
YM18, YL24
30
250
6-30R
Table 1.
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
NOTICE
Do not use the LCDI device as an ON/OFF switch.
Failure to adhere to this precaution may cause
premature equipment malfunction.
Once plugged in, the unit will operate normally without the need to reset 
the LCDI device.  If the LCDI device fails to trip when tested or if the power 
supply cord is damaged, it must be replaced with a new power supply cord 
from the manufacturer.  Contact our Technical Assistance Line at (800) 
541-6645.  To expedite service, please have your model number available.
Figure 1
FRR072
WARNING:
TEST BEFORE EACH USE!
1. PRESS REST BUTTON.
2. PLUG LCDI INTO POWER
RECEPTACLE.
3. PRESS TEST BUTTON,
RESET BUTTON SHOULD
POP UP.
4. PRESS RESET BUTTON
FOR USE.
DO NOT USE IF ABOVE TEST
FAILS.
WHEN GREEN LIGHT IS ON.
IT IS WORKING
PROPERLY!
RESET
TEST
SL22, SL24