Sharp PG-D45X3D ユーザーズマニュアル

ページ / 34
-4
RS-232C Specifi cations and Commands
Computer control
A computer can be used to control the projector by connecting an RS-232C serial control cable (cross 
type, commercially available) to the projector. (See page 24 of the projector's operation manual for 
connection.)
Communication conditions
Set the serial port settings of the computer to match that of the table.
Signal format: Conforms to RS-232C standard. 
Parity bit: None
Baud rate*: 9,600 bps / 38,400 bps / 115,200 bps 
Stop bit: 1 bit
Data length: 8 bits 
Flow control: None
*Set the projector's baud rate to the same rate as used by the computer.
Basic format
Commands from the computer are sent in the following order: command, parameter, and return code. 
After the projector processes the command from the computer, it sends a response code to the 
computer.
Command format
C1
C2 C3 C4
P1
P2
P3
P4
Return code
 (0DH)
 
Command 4-digit 
Parameter 4-digit
Response code format
Normal response 
Problem response (communication error or incorrect command)
O
K
Return code
 (0DH)
E
R
R
Return code
 (0DH)
Info
When controlling the projector using RS-232C commands from a computer, wait for at least 30 seconds 
after the power has been turned on, and then transmit the commands.
After sending an input selection or picture adjustment command and then receiving an “OK” response 
code, the projector may take some time to process the command. If a second command is sent while the 
projector is still processing the fi rst command, you may receive an “ERR” response code. If this happens, 
try resending the second command.
When more than one code is being sent, send each command only after the response code for the 
previous command from the projector is verifi ed.
“POWR????”, “TABN _ _ _ 1”, “TLPS _ _ _ 1”, “TPOW _ _ _ 1”, “TLPN _ _ _ 1”, “TLTT _ _ _ 1”, 
“TLTM _ _ _ 1”, “TLTL _ _ _ 1”, “TNAM _ _ _ 1”, “MNRD _ _ _ 1”, “PJN0 _ _ _ 1”
− When the projector receives the special commands shown above:
* The on-screen display will not disappear.
* The “Auto Power Off” timer will not be reset.
− The special commands are available for applications that require continuous polling.
If an underbar (_) appears in the parameter column, enter a space.
If an asterisk (*) appears in the parameter column, enter a value in the range indicated in brackets under 
Control Contents.

Note
PJLink
TM
 Compliant:
This product conforms with the PJLink standard Class 1 and all Class 1 commands are implemented.
This product confi rms with the PJLink standard specifi cation version 1.00.
For additional information, visit “http://pjlink.jbmia.or.jp/english/”.