Section 2 – Operation
Commercial-Industrial-Residential Portable Generator System
OPERATION
2.1 KNOW THE GENERATOR
Read the Owner’s Manual and  Safety Rules before
operating this generator.
Compare the generator to this illustration to become familiarized
with the locations of various controls and adjustments.  Save this
manual for future reference.
1)  12 Volt DC, 10 Amp Receptacle 
This receptacle
allows the capability to recharge a 12 volt DC storage battery
with provided battery charge cables.
2)  120 Volt AC, 20 Amp, Duplex Receptacle – 
Supplies
electrical power for the operation of 120 Volt AC, 20 Amp, 
single-phase, 60 Hz electrical lighting, appliance, tool and 
motor loads.
3)  120 Volt AC, 20A Duplex GFCI Receptacle – 
Supplies ground fault protected electrical power for
operation of 120 volt AC 20 amp, single-phase, 60 Hz electric
lighting, appliances, tools and motor loads.
4) 120 Volt AC, 30 Amp Locking Receptacle 
Supplies
electrical power for the operation of 120 Volt AC, 30 Amp,
single-phase, 60 Hz electrical lighting, appliance, tool and
motor loads.
5)  120/240 Volt AC, 30 Amp Locking Receptacle 
Supplies electrical power for the operation of 120 and/or 240
Volt AC, 30 Amp, single-phase, 60 Hz, electrical lighting,
appliance, tool and motor loads.
6)  120/240 Volt AC, 50 Amp Receptacle – 
Supplies
electrical power for the operation of 120/240 Volt AC, 50
Amp, single-phase, 60 Hz, welder or motor loads.
7) Air 
Cleaner 
Filters intake air as it is drawn into the engine.
8) Choke Knob 
Used when starting a cold engine.
9)  Winter / Summer Valve 
See “Cold Weather Operation.”
(Section 2, page 12.)
10) Circuit Breakers
(AC) – Each receptacle is provided with
a push-to-reset circuit breaker to protect the generator
against electrical overload. (50 amp uses toggle reset)
11) Fuel Tank – 
Tank holds 16 U.S. gallons of fuel.
12) Grounding Lug 
Ground the generator to an approved
earth ground here.  See page 9 for details.
13) Idle Control Switch 
The idle control runs the engine at
normal (high) speeds when there is an electrical load present
and runs the engine at idle (low) speeds when a load is not
present.