Infocus IN5132 ユーザーガイド

ページ / 167
122
• Although bright or dark spots may appear on the screen, this is a 
unique characteristic of liquid crystal displays, and it does not constitute or 
imply a machine defect.
NOTE
Situation
Troubleshooting tips
Reference 
page
NETWORK 
BRIDGE 
function does 
not work
The NETWORK BRIDGE function is turned off.
Set COMMUNICATION TYPE to NETWORK BRIDGE in 
the OPTION - SERVICE - COMMUNICATION menu.
72
Schedule 
function does 
not work
The SAVING function is working.
Set STANDBY MODE to NORMAL in the SETUP menu.
56
T
he internal clock has been reset.
If the projector is in SAVING mode and the projector is 
turned off (or AC power is turned off), the current date 
and time setting has been reset.
Check the DATE AND TIME settings for WIRELESS 
SETUP or WIRED SETUP in the NETWORK menu.
78, 82
When the 
projector is 
connected to 
the network, it 
powers off and 
on as described 
below.
Powers off
POWER 
indicator blinks 
orange several 
times
Goes into  
standby mode
Disconnect the LAN cable and check that the 
projector is working properly.
If this situation occurs after connecting to the network, 
there may be a loop between two Ethernet switching 
hubs within the network, as explained below.
-  There are two or more Ethernet switching hubs in the 
network.
- Two of the hubs are connected twice by LAN cables.
-  This double connection forms a loop between the two 
hubs.
Such a loop may have an adverse effect on the projector 
as well as other network devices.
Check the network connection and remove the loop by 
disconnecting the LAN cables so that there is only one  
connecting cable between the two hubs.
Troubleshooting
Problems that can be easily mistaken for machine defects (continued)