5. To mount anti-tip bracket to wood floor, drill two 
¹⁄₈" (3.2 mm) 
holes at the positions marked on the bracket template. 
Remove template from floor.
To mount anti-tip bracket to concrete or ceramic floor, use a 
³⁄₁₆" (4.8 mm) masonry drill bit to drill 2 holes at the positions 
marked on the bracket template. Remove template from floor. 
Tap plastic anchors into holes with a hammer.
6. Align anti-tip bracket holes with holes in floor. Fasten anti-tip 
bracket with screws provided.
Depending on the thickness of your flooring, longer screws 
may be necessary to anchor the bracket to the subfloor. 
Longer screws are available from your local hardware store.
7. Move range close enough to opening to allow for final 
electrical connection. Remove shipping base, cardboard or 
hardboard from under range. 
8. Move range into its final location making sure rear leveling leg 
slides into anti-tip bracket.
9. If installing the range in a mobile home, you must secure the 
range to the floor. Any method of securing the range is 
adequate as long as it conforms to the standards in the 
“Location Requirements” section.
10. Continue installing your range using the following installation 
instructions.
Make Gas Connection
Typical rigid pipe connection
A combination of pipe fittings must be used to connect the range 
to the existing gas line. Your connections may be different, 
according to the supply line type, size and location.
1. Apply pipe-joint compound made for use with LP gas to all 
pipe thread connections.
2. Using a pipe wrench to tighten, connect the gas supply to the 
range.
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the 
smaller thread ends of the flexible connector adapters (see B 
and G in following illustration). 
2. Attach one adapter to the gas pressure regulator and the 
other adapter to the gas shutoff valve. Tighten both adapters.
A. Gas pressure regulator
B. 90° elbow (must have 
½" male pipe thread)
C. Nipple
D. Union
E. Black iron pipe
F. Manual gas shutoff valve
G. ½" or ¾" gas pipe
H. Nipple
I. Union
J. 90° elbow 
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.