Marantz PD4201 ユーザーズマニュアル

ページ / 49
  PDxx01  
       RS-232C Control Specification                                                      Page: 14 / 49 
Document Version [1.0]
 
Company Restricted 
 
 
 5-15. 
GREEN Gain Data 
Function 
The external control equipment changes the GREEN Gain Data of the plasma monitor. 
 
Transmission Data 
  DFH  80H  60H  7FH  04H  DATA00 to DATA03  CKS 
 
DATA00: USER PICTURE Gain Flag     
01H 
 
DATA01: GREEN Gain Flag   
 
02H 
 
DATA02: GREEN Gain1 (Bias) 
 
D8H: -40 
  
 
 
  
FFH: 
-01 
  
00H: 
  
01H: 
+01 
  
 
  
1EH: 
+30 
 
DATA03: GREEN Gain2(Drive) 
 
D8H : -40 
  
 
 
  
FFH: 
-01 
  
00H: 
  
01H: 
+01 
 
   
  : 
  
1EH: 
+30 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER PICTURE Gain Flag     
01H 
 
DATA01: GREEN Gain Flag   
 
02H 
 
 5-16. 
BLUE Gain Data 
Function 
The external control equipment changes the BLUE Gain Data of the plasma monitor. 
 
Transmission Data 
  DFH  80H  60H  7FH  04H  DATA00 to DATA03  CKS 
 
DATA00: USER PICTURE Gain Flag     
01H 
 
DATA01: BLUE Gain Flag   
 
03H 
 
DATA02: BLUE Gain1 (Bias) 
 
D8H :-40 
  
 
 
  
FFH: 
-01 
  
00H: 
  
01H: 
+01 
  
 
  
1EH: 
+30 
 
DATA03: BLUE Gain2 (Drive) 
 
D8H:-40 
  
 
 
  
 
FFH: 
-01 
  
 
00H: 
  
 
01H: 
+01 
  
 
 
  
 
1EH: 
+30 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER PICTURE Gain Flag     
01H 
 
DATA01: BLUE Gain Flag   
 
03H