Enterasys 6000 ユーザーガイド

ページ / 420
On-line Operat ions
16-3
Rebooting the Remote Node
Before rebooting, notify all users of this node, since all connec-
tions on all ports will be cleared.
To reboot a node under remote control, follow this procedure at the controlling node:
1. Press 
[F10]
.
2. When asked: 
Remote reboot the node?
, press
 [Y]
.
3. Press 
[F9]
 to return to local control.
Exiting Remote Control
Press 
[F9]
 to stop remote control. When asked: 
Stop remote control?
, press 
[Y]
. Both 
nodes will now be under local control.
If either the controlling or the controlled node detects that the remote control link 
failed during a remote session, remote control will be terminated and each terminal's 
local main menu will be displayed.
Remote Control via Async PAD Port
Once the ANSI terminal is in 
Command 
mode (described on page C-1.), follow this 
procedure to take remote control of an FRX/FRM:
1. Enter the 
Remote Control  ID
 of the node (specified in its Node Defaults file), fol-
lowed (with no spaces) by the letter 
d
 and the 
Remote Control  Password
 of the 
node (also specified in its Node Defaults file). An example of a correct entry for 
Remote Control  ID
 of 
1234
 and a password of 
remote
 is 
1234dremote
.
2. When  the remote node accepts  your entry, you will be asked: 
Are you a PAD user?
 
Type 
y [Enter]
.
3. When prompted, enter the password of the controlled node. The display at the 
controlled node will say: 
Under  remote  control. Keyboard blocked by id =  "n." 
The 
M
ain Menu at the controlling node will act as the Main Menu of the controlled 
node, and the displayed remote ID is the ID of the controlled node.
Placing a call through the FRX/FRM is described in Appendix C.
Rebooting the Remote Node
Before rebooting, notify all users of this node, since all connec-
tions on all ports will be cleared.
Press 
[.]
  (period) to reboot the node.  When  asked: 
Remote reboot the node?
, press
 [Y]
.