TallyGenicom 2440 インストール手順

ページ / 4
2
Remove the cover. You can now see the interface socket and two guides (bottom,
top)
A
.
3
Take the interface module and make sure that the two screw openings are pointing
to the right. Slide the interface module into the guides and push it carefully into the
printer until the connector of the interface module is properly seated into the socket.
4
Fasten the interface module with the two screws to the printer. The left example
shows the RS232C interface, the right example the Ethernet interface.
5
Connect the interface cable to the printer and the computer.
Serial interface
The optional serial interface module supports the RS232C specification. The signals
are received and transmitted by a 25 pin female connector.
Use a serial interface cable that meets the requirements of your host PC.
Type
RS232C interface
Data rates
4800 bps, 9600 bps, 19200 bps, 38400 bps
Synchronization
Asynchronous
Signal status
Off (log. 1): –3 V to –15 V
On (log. 0): +3 V to +15 V
Cable length
up to 15 m
Interface connector
ITT Cannon connector, series DB-25 S
Transmission protocol