TallyGenicom 34ppm インストール手順

ページ / 24
Publication No. GEG-99203
Nov 04
3-2
RS232/422 Installation Guide for the 34ppm Laser Printer
Control Panel Error Messages
About this Chapter
This chapter discusses troubleshooting error messages appearing on the printer’s control panel. 
Sources of help, information and technical support are also discussed.
Control Panel Error Messages
The format of control panel error messages is:
NETx: ERROR y
where x indicates the network slot where the serial interface is installed
and
where y reflects the error number as shown below:
Example
An error message of:
NET2: ERROR3
indicates that the serial interface which is located in network slot 2 has experienced a framing error. 
Obtaining Help and Information
Several sources of help and information are available, depending on the type of help you need:
Error No.
Description
Action Required
1
Overrrun Error
Verify that all DTS, RTS and XON settings within 
the SERIAL SETUP menu are configured correctly.
Check the pinout assignments of cabling between 
the printer and the host.
2
Parity Error
Verify that the PARITY setting within the SERIAL 
SETUP menu is configured correctly.
Check the pinout assignments of cabling between 
the printer and the host.
3
Framing Error
Verify that the SERIAL MODE, BAUD RATE, DATA 
BITS, STOP BITS and PARITY settings within the 
SERIAL SETUP menu are configured correctly.
4
Flow Control Error
Verify that all DTS, RTS and XON settings within 
the SERIAL SETUP menu are configured correctly.
Check the pinout assignments of cabling between 