Chapter 25      Configuring BXM Virtual Trunks
Example: Virtual Trunk Across an ATM Network
A virtual trunk is added between port 3 on the BXM and port 2 on the UXM (see Figure 25-6).
Given this situation, you would perform these steps:
The VPI values you choose by using cnftrk must match those used by the cloud VPC.
In addition, both ends of the virtual trunk must match with respect to:
Transmit Rate
VPC type
1.
Initial Setup
Contact Customer Service to enable virtual trunking
on the nodes in your network.
2.
In the public
ATM cloud
Obtain the VPCs for the virtual trunks for the service
provider. These are the VPCs that are configured
within the ATM cloud by the service provider to
support the virtual trunks.
3.
At BPX_A
uptrk 4.3.1
uptrk 4.3.2
Up virtual trunks 4.3.1 and 4.3.2 on BXM port 4.3.
4.
At BPX_A
cnftrk 4.3.1 ...
cnftrk 4.3.2 ...
Configure the virtual trunks to match the cloud’s VPC
configuration, including: VPI, header type (UNI or
NNI), traffic classes, and VPC type, and so on.
5.
At BPX_A
cnfrsrc 4.3.1 ...
cnfrsrc 4.3.2 ...
Configure the number of conids, bandwidth, and so on,
available for the virtual trunks.
6.
At BPX_B
uptrk 5.1.1
uptrk 5.1.2
Up virtual trunks 5.1.1 and 5.1.2 on BXM port 5.1.
7.
At BPX_B
cnftrk 5.1.1 ...
cnftrk 5.1.2 ...
Configure the virtual trunks to match the cloud’s VPC
configuration, including: VPI, header type (UNI or
NNI), traffic classes, and VPC type, and so on.
8.
At BPX_B
cnfrsrc 5.1.1 ...
cnfrsrc 5.1.2 ...
Configure the number of conids, bandwidth, and so
on., available for the virtual trunks.
9.
At IGX_A
uptrk 10.2.1
uptrk 10.2.3
Up virtual trunks 10.2.1 and 10.2.3 on IGX trunk port
10.2.
10.
At IGX_A
cnftrk 10.2.1 ...
cnftrk 10.2.3 ...
Configure the virtual trunks to match the cloud’s VPC
configuration, including: VPI, header type (UNI or
NNI), traffic classes, and VPC type, and so on.
11.
At IGX_A
cnfrsrc 10.2.1 ...
cnfrsrc 10.2.3 ...
Configure the number of conids, bandwidth, and so on,
available for the virtual trunk.
12.
At BPX_A
addtrk 4.3.1 IGX_A
10.2.1
addtrk 4.3.2 BPX_B
5.1.1
Add the virtual trunks between three nodes. Using
addtrk 10.2.1 ... at IGX_A and addtrk 5.1.1 ... at
BPX_B would also add the virtual trunks.
13.
At BPX_B
addtrk 5.1.2 IGX_A
10.2.3
Add the virtual trunks between the two nodes. Using
addtrk 10.2.3 ... at IGX_A would also add the virtual
trunks.