Cisco slm224g4ps ユーザーズマニュアル

ページ / 78
Chapter 5
Configuration Using the Web-based Utility
28
24/48-Port 10/100 + 4-Port Gigabit Smart Switch with Resilient Clustering Technology and PoE
Oversize  Packets 
Displays  the  number  of  oversized 
packets (over 1518 octets) received on the interface since 
the device was last refreshed.
Fragments 
Displays  the  number  of  fragments  (packets 
with  less  than  64  octets,  excluding  framing  bits,  but 
including FCS octets) received on the interface since the 
device was last refreshed.
Jabbers 
Displays  the  total  number  of  received  packets 
that were longer than 1518 octets. This number excludes 
frame bits, but includes FCS octets that had either a bad 
Frame Check Sequence (FCS) with an integral number of 
octets (FCS Error) or a bad FCS with a non-integral octet 
(Alignment  Error)  number.  The  field  range  to  detect 
jabbers is between 20 ms and 150 ms.
Collisions 
Displays the number of collisions received on 
the interface since the device was last refreshed.
Utilization 
Displays the percentage of the interface utilized.
Statistics > RMON Alarms
The  RMON  Alarm  screen  is  used  to  set  network  alarms. 
Network alarms occur when a network problem, or event, 
is detected. Rising and falling thresholds generate events.
Statistics > RMON Alarm
Add Alarm
Alarm Entry 
Indicates a specific alarm.
Interface 
Indicates  the  interface  for  which  RMON 
statistics  are  displayed.  To  specify  the  interface,  select 
Unit No. (default) and specify the unit number and port 
from the drop-down menus, or select LAG  and select the 
LAG number from the drop-down menu.
Counter Name 
Displays the selected MIB variable.
Sample  Type 
Defines  the  sampling  method  for  the 
selected  variable  and  comparing  the  value  against  the 
thresholds. The possible field values are:
Absolute 
Compares  the  values  directly  with  the 
thresholds at the end of the sampling interval.
Delta 
Subtracts  the  last  sampled  value  from  the 
current value. The difference in the values is compared 
to the threshold.
Rising Threshold 
Displays the rising counter value that 
triggers  the  rising  threshold  alarm. The  rising  threshold 
is  presented  on  top  of  the  graph  bars.  Each  monitored 
variable is designated a color.
Rising Event 
Displays the mechanism in which the alarms 
are reported. The possible field values are: 
LOG 
Indicates  there  is  not  a  saving  mechanism  for 
either the device or in the management system. If the 
device is not reset, the entry remains in the Log Table. 
TRAP 
Indicates that an SNMP trap is generated, and 
sent  via  the  Trap  mechanism.  The  Trap  can  also  be 
saved using the Trap mechanism. 
Both 
 Indicates that both the Log and Trap mechanism 
are used to report alarms.
Falling Threshold 
Displays the falling counter value that 
triggers the falling threshold alarm. The falling threshold 
is  graphically  presented  on  top  of  the  graph  bars.  Each 
monitored variable is designated a color.
Falling  Event 
Displays  the  mechanism  in  which  the 
alarms are reported. The possible field values are:
LOG 
Indicates  there  is  not  a  saving  mechanism  for 
either the device or in the management system. If the 
device is not reset, the entry remains in the Log Table. 
TRAP 
Indicates  that  a  SNMP  trap  is  generated,  and 
sent  via  the  Trap  mechanism.  The  Trap  can  also  be 
saved using the Trap mechanism. 
Both 
Indicates that both the Log and Trap mechanism 
are used to report alarms.
Startup Alarm 
Displays the trigger that activates alarm 
generation.  Rising  is  defined  by  crossing  the  threshold 
from a low-value threshold to a higher-value threshold.
Interval 
Defines the alarm interval time in seconds.
Owner 
Displays the device or user that defined the alarm.
Click Add to List to add an entry to the Alarm Table.
Alarm Table
The Alarm Table lists the alarms that have been defined 
using the Add Alarm section. The Alarm Table contains a 
colunn for each field in the Add Alarm section, plus the 
following column:
Counter Value 
Displays the current counter value for the 