Alcatel-Lucent 6850-48 補足マニュアル

ページ / 312
Managing CMM Directory Content
Managing Redundancy in a Stack and CMM
OmniSwitch AOS Release 6 Switch Management Guide
September 2009
page 5-25
Synchronizing the primary and secondary CMMs is done using th
described in 
.
Note. If a switch fails over to the secondary CMM, it is necessary to have a management interface connec-
tion to the secondary CMM (such as an Ethernet port or a console port).
Copying the Working Directory to the Certified Directory
Synchronizing the Primary and Secondary CMMs
At the same time that you copy the working directory to the certified directory, you can synchronize the 
secondary CMM with the primary CMM. In the case of redundant CMMs, this ensures that the two 
modules are booting from the same software.
To copy the working directory to the certified directory of the primary CMM and at the same time 
synchronize the software of the primary and secondary CMM, use the following command:
-> copy working certified flash-synchro
Note. This command will not function if the switch is running from the certified directory. See 
 for an explanation.
 command will synchronize all switches in a stack of switches. This command 
is described in detail in the OmniSwitch CLI Reference Guide.
Note. When synchronizing the primary and secondary CMMs, it is important to remember that the 
boot.params file and the switch date and time are not automatically synchronized. See the appropriate 
Getting Started Guide for information on the boot.params file, and 
 
for information on setting the switch date and time. The date and time are synchronized using the