Ethernet OAM Specifications
Configuring Ethernet OAM
page 15-2
OmniSwitch AOS Release 6 Network Configuration Guide
September 2009
Ethernet OAM Specifications
The following table lists Ethernet OAM specifications. 
Ethernet OAM Defaults
The following table shows Ethernet OAM default values.
IEEE Standards Supported
IEEE 802.1ag–Connectivity Fault Management
IEEE 802.3ah–CSMA/CD Access Method and Physical 
Layer Specifications
IEEE 802.1D–Media Access Control (MAC) Bridges
IEEE 802.1Q–Virtual Bridged Local Area Networks
Platforms Supported
OmniSwitch 6400, 6850, 6855, and 9000
Maximum Maintenance Domains (MD) 
per Bridge

4 (OmniSwitch 6400)
Maximum Maintenance Associations 
(MA) per Bridge
128
64 (OmniSwitch 6400)
Maximum Maintenance End Points 
(MEP) per Bridge
256 
128 (OmniSwitch 6400)
Maximum MEP CMM Database Size
(NoteThis max value was not included 
in Specs table prior to 6.3.3.)
8192 
4092 (OmniSwitch 6400)
Parameter Description
Command
Default Value/Comments
MHF value assigned to a default 
Ethernet OAM Maintenance Domain
none
Continuity Check Message interval
interval10s
The priority value for CCMs and 
LTMs transmitted by the MEP
7
The lowest priority fault alarm for 
the lowest priority defect for a MEP
mac-rem-err-xcon
Number of Loopback messages to be 
transmitted
1
Data Type Length Value
64
VLAN priority
0
Whether or not Drop Enable bit is 
configured (true or false)
true
Hop count
64
Fault notification generation alarm 
time
250 centiseconds