The following table shows LINK OAM default values.
Parameter Description
Command
Default Value/Comments
Multiple PDU count assigned for 
event notifications.
3
Maximum time period for which a 
LINK OAM port shall wait for a 
hello message from its peer before 
resetting a discovery session.
5 seconds
Time interval (in seconds) by which 
the information OAMPDUs are 
transmitted out of an LINK OAM 
enabled port.
1 second
Propagate local event notifications 
to the remote peer.
critical event - enabled
dying-gasp event - enabled.
The threshold, window frame values 
and notify status for errored frame 
period events.
threshold_symbols - 1 frame 
error
window_frames - Depends on 
port types.
notify status - enable
The threshold, window, and notify 
status for errored frame events.
threshold_symbols - 1 frame 
error
window_seconds - 1 second 
notify status - enable
The threshold, window and notify-
status for errored-frame-seconds-
summary on a port.
threshold_symbols - 1 errored 
frame second
window_seconds - 60 seconds.
notify status - enable
The number of frames sent by the 
current LINK OAM port to the 
MAC address of the remote port, the 
delay between the frames sent, and 
whether or not to start the ping oper-
ation.
number - 5 frames
milliseconds - 1000