Alcatel-Lucent 6850-48 ネットワークガイド
Configuring Link Monitoring
Configuring EFM (LINK OAM)
page 16-10
OmniSwitch AOS Release 6 Network Configuration Guide
September 2009
-> efm-oam port 2/1-10 propagate-events dying-gasp enable
Note. The above commands are optional. By default, propagation of critical events and dying gasp is
enabled on the port.
enabled on the port.
Configuring Link Monitoring
Link monitoring is used to detect and indicate link faults in various environments. Link monitoring uses
the Event Notification OAMPDU, and sends events to the remote OAM node when there is a disorder
detected on the link. For more information on error events, see
the Event Notification OAMPDU, and sends events to the remote OAM node when there is a disorder
detected on the link. For more information on error events, see
Enabling and Disabling Errored frame period
Configure the threshold, window frame values and notify status for errored frame period events on the port
by using the
by using the
command.
-> efm-oam port 2/1-10 errored-frame-period window 3000000 threshold 1 notify
enable
To disable notification of errored frame period events, use the following command.
-> efm-oam port 2/1-10 errored-frame-period notify disable
Enabling and Disabling Errored frame
Configure the threshold, window, and notify status for errored frame events on the port by using the
command.
-> efm-oam port 2/1-10 errored-frame window 32 threshold 10 notify enable
To disable notification of errored frame events, use the following command.
-> efm-oam port 2/1-10 errored-frame notify disable
Enabling and Disabling Errored frame seconds summary
Configure the threshold, window and notify-status for errored-frame-seconds-summary on the port by
using the
using the
-> efm-oam port 2/1-10 errored-frame-seconds-summary window 700 threshold 1 notify
enable
enable
To disable notification of errored frame events, use the following command.
-> efm-oam port 2/1-10 errored-frame-seconds-summary notify disable