Alcatel-Lucent 6850-48 参照ガイド

ページ / 3444
OSPF Commands
page 41-34
OmniSwitch CLI Reference Guide
September 2009
ip ospf interface hello-interval
Configures the OSPF interface hello interval.
ip ospf interface {interface_name} hello-interval seconds
Syntax Definitions
interface_name
The name of the interface.
seconds
The hello interval, in seconds. The valid range is 1–65535.
Defaults
Platforms Supported
OmniSwitch 6850, 6855, 9000, 9000E
Usage Guidelines
This is the interval between two consecutive hello packets sent out on this interface.
Examples
-> ip ospf interface vlan-101 hello-interval 50
Release History
Release 6.1; command was introduced.
Release 6.2.1; ip_address parameter deprecated.
Related Commands
MIB Objects
ospfIfTable
ospfIfHelloInterval
parameter
default
seconds
(broadcast and point-to-point)
10
seconds
(NBMA and point-to-multi-
point)
30
Displays the status and statistics of an OSPF interface.