OSPFv3 Commands
page 42-18
OmniSwitch CLI Reference Guide
September 2009
ipv6 ospf interface dead-interval
Configures the OSPFv3 interface dead interval.
ipv6 ospf interface interface_name dead-interval seconds
Syntax Definitions
interface_name
The name of the interface.
seconds
The dead interval, in seconds. The valid range is 1–65535.
Defaults
Platforms Supported
OmniSwitch 6850, 6855, 9000, 9000E
Usage Guidelines
• After the dead interval, a neighbor on this interface is considered dead if no hello packets have been 
received from this neighbor.
• This interval should be greater than the hello interval or multiples of the hello interval.
Examples
-> ipv6 ospf interface vlan-101 dead-interval 50
Release History
Release 6.1.3; command was introduced.
parameter
default
seconds
(broadcast and point-to-point)
40
seconds
(NBMA and point-to-multi-
point)
120