Alcatel-Lucent 6850-48 参照ガイド

ページ / 3444
PIM Commands
OmniSwitch CLI Reference Guide
September 2009
page 45-33
ip pim invalid-register-notification-period
Specifies the minimum time that must elapse between the PIM invalid register notifications originated by 
the router. 
ip pim invalid-register-notification-period seconds
Syntax Definitions
seconds
Specifies the minimum time value that must elapse between invalid 
register notifications, in seconds (10–65535).
Defaults
Platforms Supported
OmniSwitch 6850, 6855, 9000, 9000E
Usage Guidelines
• The default value of 65535 represents an infinite time. The PIM invalid register notifications are never 
sent in case of infinite time.
• The non-zero minimum allowed value provides resilience against the propagation of denial-of-service 
attacks from the data and control planes to the network management plane.
• This value is used with both IPv4 and IPv6 PIM.
• This command is supported only in the sparse mode.
Examples
-> ip pim invalid-register-notification-period 100
Release History
Release 6.3.1; command was introduced.
Related Commands
MIB Objects
alaPim
alaPimInvalidRegisterNotificationPeriod
parameter
default
seconds
65535
Displays the configuration of the configured notification periods as 
well as information on the events triggering the notifications.