Ethernet Port Commands
page 19-50
OmniSwitch CLI Reference Guide
September 2009
interfaces hybrid speed
Configures interface line speed on combo ports.
interfaces slot[/port[-port2]] speed hybrid {fiber | copper} {auto | 10 | 100 | 1000 | 10000 | max {100 | 
1000}}
Syntax Definitions
slot
Slot number you want to configure.
port
Port number of the interface you want to configure.
port2
Last port number in a range of ports you want to configure.
fiber
Specifies that configuration changes will be made to the SFP port(s).
copper
Specifies that changes will be made to the copper 10/100/1000 RJ-45 
port(s).
auto
The switch will automatically set the line speed to match the attached 
device (auto-sensing).
10
Sets the interface to 10 Mbps.
100
Sets the interface to 100 Mbps.
1000
Sets the interface to 1 Gigabit.
10000
Sets the interface to 10 Gigabit. This option is currently not supported.
max 100
Sets the maximum speed to 100 megabits.
max 1000
Sets the maximum speed to 1000 megabits (1 Gigabit)
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855
Usage Guidelines
• Refer to the Hardware Users Guide for combo port numbering. 
• The MIB table and MIB object listed in the “MIB Objects” section below apply to the inactive config-
ured media only. See the “MIB Objects” section in the 
 section for the MIB table and 
MIB object for the active configured media.
parameter
default
auto | 10 | 100 | 1000 | 
10000 | max 100 | max 
1000
auto