GVRP Commands
OmniSwitch CLI Reference Guide
September 2009
page 22-11
gvrp timer 
Configures the Join, Leave, or LeaveAll timer values for the switch ports.
gvrp timer {join | leave | leaveall} timer-value {linkagg agg_num | port slot/port}
no gvrp timer {join | leave | leaveall} {linkagg agg_num | port slot/port}
Syntax Definitions
join
Specifies the
 
value of the Join timer in milliseconds.
leave
Specifies the value of the Leave timer in milliseconds.
leaveall
Specifies the value of the LeaveAll timer in milliseconds.
timer-value
The value of the specified timer in milliseconds. The valid range is
1–2,147,483,647 for Join timer, 3–2,147,483,647 for Leave timer, and
3–2,147,483,647 for LeaveAll timer.
agg_num
The number corresponding to the aggregate group.
slot/port 
The slot number for the module and the physical port number on that 
module (e.g., 3/1 specifies port 1 on slot 3).
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
• Use the no form of this command to set the timer for a particular slot or port to the default value.
• GVRP should be enabled on the port before configuring the timer value for that port.
• Leave timer value should be greater than or equal to three times the Join timer value.
• Leaveall timer value should be greater than or equal to the Leave timer value.
• To use the agg_num parameter, the link aggregate group should be created and enabled.
parameter
default
timer-value (join)
600 ms
timer-value (leave)
1800 ms
timer-value (leaveall)
30000 ms