page 2-25
temp-threshold
Sets the CPU warning temperature threshold for the switch.
temp-threshold temp slot slot-number
Syntax Definitions
temp
The new temperature threshold value, in Celsius.
slot-number
The chassis slot number for which the CPU warning temperature 
threshold is set.
 
This parameter is supported only on stackable switches.
Defaults 
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E.
Usage Guidelines
Use th
 command to display the current value for the temerpature warning threshold. 
Do not use th
 command as it does not display temperature threshold information.
Examples
-> temp-threshold 45
-> temp-threshold 55 slot 2
Release History
Release 6.1; command was introduced.
Release 6.1.5; slot parameter added.
Related Commands
MIB Objects
chasChassisTable
chasTempThreshold
parameter
default
temp
60
Displays the current operating chassis ambient temperature, as well as 