Alcatel-Lucent 6850-48 参照ガイド
Chassis Management and Monitoring Commands
OmniSwitch CLI Reference Guide
September 2009
page 2-25
temp-threshold
Sets the CPU warning temperature threshold for the switch.
temp-threshold temp slot slot-number
Syntax Definitions
temp
The new temperature threshold value, in Celsius.
slot-number
The chassis slot number for which the CPU warning temperature
threshold is set.
threshold is set.
This parameter is supported only on stackable switches.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E.
Usage Guidelines
Use the
command to display the current value for the temerpature warning threshold.
Do not use the
command as it does not display temperature threshold information.
Examples
-> temp-threshold 45
-> temp-threshold 55 slot 2
Release History
Release 6.1; command was introduced.
Release 6.1.5; slot parameter added.
Release 6.1.5; slot parameter added.
Related Commands
MIB Objects
chasChassisTable
chasTempThreshold
parameter
default
temp
60
Displays the current operating chassis ambient temperature, as well as
current temperature threshold settings.
current temperature threshold settings.