Amcor AM-70 オーナーマニュアル

ページ / 4
2
7
The AMCOR Ultra Clean Ficus Tree Air Purifier is safe.  Its AC/DC adaptor has been
listed by UL.  However, as with other electrical appliance, use it with care.
•  Do not clean the AMCOR Ultra Clean Ficus Tree Air Purifier by spraying it or
immersing it in water.
•  Do not insert any foreign object into any of the openings of the
AMCOR Ultra Clean Ficus Tree Air Purifier.
•  Disconnect from the electrical outlet before cleaning the unit or
any of its components.
•  Do not connect to an electrical outlet using an extension cord.
If an outlet is not available, one should be installed by a licensed electrician.
• Do not operate this unit if an oxygen tent or similar concentrated
oxygen generating device is present in the room, or in a work area with bottled 
gases.  However, the unit is safe to operate near a well-maintained gas stove.
• A slight sensation may be felt if the carbon filament ionizing element
(the carbon cord on the front air outlet) is touched.  This is normal and presents
no danger.  This sensation may also be felt if you touch a person or a large metal
object while your other hand is on the unit.
Warning:
Any service other than regular cleaning or filter replacement should be performed
by an authorized service representative.  Failure to do so could result in a loss
of warranty.
Warning:
If the AC/DC adaptor or its supply cord are damaged, then the AC/DC adaptor must
be replaced by a new one purchased from Amcor.
Warning:
Even though this looks like a real tree, it does not need watering.
Do not pour water into the pot as this could create a safety hazard.
Safety
Technical Data
Power Supply:
120 V /60 Hz
Installation: 
No installation required.  Plugs into any electrical outlet
using the UL listed transformer. Transformer converts
120 V to 12 Volts and comes with a 6 foot cord.
Control Switch: Off / High Speed with Ionization / Low Speed with Ionization
Power
Consumption:
High speed:  9 W
Low speed:  7 W
AIR DELIVERY
Speed
Washable Filter
HEPA Filter
HIGH - powerful air purification
28 cfm
15 cfm
LOW - quiet operation
14 cfm
7 cfm
cfm = cubic feet per minute air delivery
Total Negative Ion Output:
2.5 x 10
12
 = 2.5 trillion negative ions per second
Ionization Voltage:
-5.5KV Ionization voltage has been optimally selected.  It will provide an ample
supply of negative ions in the room and at the same time, minimize deposits of
pollutants in the immediate vicinity of the unit.  Short current to ground is less than
0.1 milliamperes.  Direct contact with the carbon ionizing filament is completely safe.
Effective Range: Covers an area of 240 sq. ft.
Dimensions:
13.4"L  x  13.4"W  x  47.2"H
Net Weight:
15.4 lb.