Jenn-Air jmw8530da インストール手順

ページ / 21
2
NOTES
Z
Do not block air exhaust slots along bottom of
oven.
CAUTION
For European style cabinets (flush front) the
required clearance for operation of the oven door
is minimum spacing of 7/8
²
between the cutout
and the door, hinge or drawer of the cabinet.
Some built-in cabinets may not be wide enough,
due to their construction, to allow this installation.
COMBINATION WALLOVEN CUTOUT
27
² WALL OVEN DESCRIPTION
1
1-1/4
²
Dia. Conduit Access Hole*
2
5/8
²
Plywood Floor (Must Support 275 lbs.)
DIMENSIONS
in
cm
A
27 MIN
68.58 MIN
B
24 MIN
60.96 MIN
C
51-7/8 + 1/16
131.76 + .16
D
24 MIN
60.96 MIN
E
25-1/2 + 1/16
64.77 + .16
F
52-15/16
134.46
G
26-3/4
67.95
H
25-7/16
64.61
I
4 to 10
10.2 to 25.4
30
² WALL OVEN DESCRIPTION
1
1-1/4
²
Dia. Conduit Access Hole*
2
5/8
²
Plywood Floor (Must Support 275 lbs.)
DIMENSIONS
in
cm
A
30 MIN
76.20 MIN
B
24 MIN
60.96 MIN
C
51-7/8 + 1/16
131.76 + .16
D
24 MIN
60.96 MIN
E
28-1/2 + 1/16
72.39 + .16
F
52-15/16
134.46
G
29-3/4
75.57
H
25-7/16
64.61
I
4 to 10
10.2 to 25.4
* Hole must be cut as close to corner of cabinet as possible.
INSTALLATION
INSTRUCTIONS
Built-In 27
²²²² & 30²²²² Electric
Combination Wall Ovens
403 WEST FOURTH STREET, NORTH
NEWTON, IA 50208
NOTE:
INSTALLED WALL OVEN OVERLAPS
CUTOUT 15/16
²
(2.38 CM) AT THE
TOP AND 1/8
²
(0.32 CM) AT THE
BOTTOM.
THIS MUST BE TAKEN INTO
CONSIDERATION WHEN LOCATING
CUTOUT IF INSTALLED UNIT IS TO
BE CENTERED IN THE CABINET.
A
B
C
D
1
2
E
G
H
Z
F
I
Art #: 9220-028