Traulsen rif264lut-fhs ユーザーズマニュアル

ページ / 4
Project
Quantity
Item #
Model Specified:
CSI Section 11400
TRAULSEN
4401 BLUE MOUND RD.
FT. WORTH, TX 76106
PHONE 1 (800) 825-8220
FAX-MKTG. 1 (817) 624-4302
Website: www.traulsen.com
SECTION
7-6
Specifications
Refrigeration System - Refrigerator Models
A top mounted, self-contained, balanced refrigeration system using R-134a
refrigerant is conveniently located behind the one piece louver assembly. It features
a plenum effect blower coil, large, high humidity evaporator coil located outside the
food zone, and a top mounted non-electric condensate evaporator.  Standard
operating temperature is 36 to 38°F.
Refrigeration System - Freezer Models
A top mounted, self-contained, balanced refrigeration system using R-404A
refrigerant is conveniently located behind the one piece louver assembly. It features
a plenum effect blower coil, large, high humidity, interior mounted mullion coils, and
an automatic preset time activated electric defrost.  A floor drain or optional electric
condensate evaporator is required for condensate removal.  Standard operating
temperature is 0 to -5°F.
Interior
Readily removable, interior-mounted, stainless steel guides for rack are provided for
protection. Maximum rack size with wheels inboard of frame is 27" wide by 29" deep
by 66" high. Racks supplied by others.
Warranties
Both a one year parts and labor warranty and a five year compressor warranty (self-
contained models only) are provided standard.  An optional 2
nd
 year extended parts
and labor warranty is also available. In addition the INTELA-TRAUL
®
  control is
warranted by a two year parts and labor warranty.
NOTE: When ordering please specify: Voltage, Hinging, Door Size, Options and
any additional warranties. For fast order entry: Fax 1 (800) 765-8728.
Continued product development may necessitate specification changes without notice.
Part No. TR35808 (revised 1/07)
NOTES
NOTE: Figures in parentheses reflect metric equivalents.
1=
 Based on a 90 degree F ambient and 20 degree F evaporator for refrigerators and a 90 degree F
ambient and -10 degree F evaporator for freezers.
2=
 Wattage is determined by listed amps X listed volts X an average run time of 70% for refrigerators and
80% for freezers.
3=
For approximate remote weights deduct 40 lbs. from respective net or gross weight.  For other
information on remote models, please refer to spec sheet 12-2.
4=
Shipped in two cartons for assembly at job site. For total shipping weight, double figure shown.
DIMENSIONAL DATA
RRI264LUT
RRI364LUT
RIF264LUT
RIF364LUT
Net capacity cu. ft.
154.5 (4377 cu l)
239.0 (6771 cu l)
154.5 (4377 cu l)
239.0 (6771 cu l)
Length - overall in.
68 (172.7 cm)
100
1
 (255.3 cm)
68 (172.7 cm)
100
1
 (255.3 cm)
Depth - overall in.
67
9
16
 (171.6 cm)
67
9
16
 (171.6 cm)
67
9
16
 (171.6 cm)
67
9
16
 (171.6 cm)
Depth - over body in.
64 (162.6 cm)
64 (162.6 cm)
64 (162.6 cm)
64 (162.6 cm)
Depth - with door open
95
1
4
 (241.9 cm)
95
1
4
 (241.9 cm)
95
1
4
 (241.9 cm)
95
1
4
 (241.9 cm)
90 degrees in.
Clear door width in.
27
1
16
 (68.8 cm)
27
1
16
 (68.8 cm)
27
1
16
 (68.8 cm)
27
1
16
 (68.8 cm)
Clear door height in.
66
5
16
 (168.4 cm)
66
3
8
 (168.6 cm)
66
5
16
 (168.4 cm)
66
3
8
 (168.6 cm)
Height - overall in.
83
1
4
 (211.5  cm)
83
1
4
 (211.5  cm)
83
1
4
 (211.5  cm)
83
1
4
 (211.5  cm)
Rack Capacity
4
6
4
6
Net Wt. lbs.
700 (318 kg)
980 (445 kg)
820 (372 kg)
1130 (513 kg)
ELECTRICAL DATA
Voltage
208-230/115/60/1
208-230/115/60/1
208-230/115/60/1
208-230/115/60/1
Feed wires with Ground
4
4
4
4
Full load amperes
17.0
19.2
22.0
31.6
Wattage
1
2475
2795
3660
5258
REFRIGERATION DATA
Refrigerant
R-134a
R-134a
R-404A
R-404A
BTU/HR H.P.
2
8400 (2 x 
 1
2
 HP)
10240 (2 x 
 3
4
 HP) 10440 (2 x 1 HP)
15160 (4 x 
 3
4
 HP)
Construction, Hardware and Insulation
Cabinet exterior, including front, one piece sides, louver assembly and doors are
constructed of heavy gauge stainless steel. Cabinet interior and door liners are
constructed of stainless steel. Exterior cabinet top, back and bottom are constructed
of heavy gauge aluminized steel. The interior floor is constructed of stainless steel
and insulated with 
3
4
" of resilient cork. A readily attachable stainless steel ramp is
provided.
Doors are equipped with heavy-duty, extruded wiper gasket for sealing to bottom
ramp, removable plug cylinder locks and guaranteed for life cam-lift, gravity
action, self-closing metal, glide hinges with stay open feature at 120 degrees. Hinges
include a switch to automatically activate the interior incandescent lighting.
Guaranteed for life, work flow door handle is mounted horizontally over recess in
door which limits protrusion from door face into aisleways.
Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal.
Anti condensate heaters are located behind each door opening.
Cabinet and door contains high density, non-CFC, foamed in place polyurethane
insulation.
Controller
The easy to use water resistant  INTELA-TRAUL
®
 microprocessor control system is
supplied standard. Unit is NAFEM Data Protocol communication (NDP) ready.
Optional hardware required to be NDP compliant.  Third party software required for
network connection.  It includes a 3-Digit LED Display, Fahrenheit or Celsius
Temperature Scale Display Capability, Defrost Lockout Feature (freezer models only)
and an RS485 data port.  In addition it includes audio/visual alarms for: Hi/Lo Cabi-
net Temperature, Door Open, Clean Condenser, Evaporator Coil and Discharge Line
Sensor Failures, and Power  Supply Interruption.
REQUIRED CLEARANCES
In order to assure optimum performance, the condensing unit MUST have an adequate supply of
air for cooling purposes.  Therefore, the operating location must either have a minimum of 12”
clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit.
Clearance of at least 12” above is required in order to perform certain maintenance tasks.