Printronix L5020 ユーザーズマニュアル

ページ / 248
Centronics Parallel Interface
231
Centronics Parallel Interface Signals
The Centronics interface signals are defined below.
PAPER EMPTY (PE) - A high true level from the printer to indicate 
the printer is in a fault condition.
SELECT - A high true level from the printer to indicate the printer is 
ready for data transfer and the ONLINE key has been activated.
BUSY - A high true level from the printer to indicate the printer 
cannot receive data.
ACKNOWLEDGE - A low true pulse from the printer indicating the 
character or function code has been received and the printer is 
ready for the next data transfer.
DATA STROBE - A low true, 100 ns minimum pulse from the host 
to clock data into the printer. 
DATA LINES - Eight standard or inverted levels from the host that 
define the data, which may consist of a character or function code. 
Sensing Data Line 8 is controlled by printer configuration. 
PAPER INST - Optional VFU control signal from the host with the 
same timing and polarity as the data lines. Sensing of the PAPER 
INST line (PI line) is controlled by printer configuration.
PRIME - Optional low true signal from the host used to reset the 
printer to its default power-up state.
NFAULT - A low true level from the printer to indicate the printer is 
in a fault condition.
NOTE: The PAPER INST line must be disabled (configuration 
option selected from the control panel) if the host computer 
does not drive or control it. If the line is not controlled by the 
host and PAPER INST line sensing is enabled in the 
printer, rapid paper slewing occurs.