Printronix L5020 ユーザーズマニュアル

ページ / 248
Chapter 3
Printer Configuration
78 
The False setting causes the printer to never assert the DTR 
signal.
The On/Offline&Buf setting (the default setting) causes the 
printer to assert the DTR signal only when the printer is online 
and its internal serial buffer is not full.
The On/Offline setting causes the printer to assert the DTR 
signal whenever either the printer is offline or its internal serial 
buffer is full.
RTS (Request To Send) Function
Values: On/Offline&Buf (default), True, False or On/Offline.
This parameter must be set to match your host computer.
The RTS Function parameter is part of hardware flow control. This 
parameter determines when the printer generates the Request to 
Send (RTS) signal to the host computer. RTS is a status signal that 
the printer sends to the host to indicate whether or not the printer is 
ready to receive data.
The True parameter setting causes the printer to assert 
continuously the RTS signal.
The False setting causes the printer to never assert the RTS 
signal.
The On/Offline&Buf setting (the default setting) causes the 
printer to assert the RTS signal only when the printer is online 
and its internal serial buffer is not full.
The On/Offline setting causes the printer to assert the RTS 
signal whenever either the printer is offline or its internal serial 
buffer is full.
DTR Polarity
Values: Normal (default) or Inverted.
This parameter must be set to match the DTR signal polarity of your 
host computer.
This parameter enables the DTR signal to invert if required for a 
particular installation.