Printronix L1524 ユーザーズマニュアル

ページ / 130
116
Chapter
3
Job Capture
Twinax Host Data
Coax Host Data
C/T Base Emulation
PCI Ethernet In
USB In
NOTE: The USB port is available only on SL5000r/T5000r printers.
Triggers
Figure 96. Configure Triggers Window
A Trigger allows a selective capture of host data. You need to specify two 
triggers, a start trigger and an end trigger. Select TriggersConfigure.
See Figure 96.
Enter triggers as text or hex strings with a maximum length of 256 characters. 
Job Capture scans received data for the start trigger sequence. Once found, 
data capture begins and continues until Job Capture finds the end trigger.
If you do not set a start trigger, all data is captured when the Job Capture 
starts. If you do not set an end trigger, the data will continue to capture until 
you stop it.
A second trigger option is a trigger count. You can set Job Capture to start or 
stop once it finds a set number of start and/or stop triggers. The window that 
displays captured data shows any lines containing start triggers and highlights 
the start trigger strings. You can also use the Search feature to search 
through captured data.
The Ignore Case check box allows character case to be ignored. Check the 
box to search for a string regardless of character case, and the data will 
capture once the string is found.
NOTE: You cannot apply triggers to Coax/Twinax and TCP/IPDS jobs.
Options
Disable Printing
Select OptionsDisable Printing to capture data without printing.