Running Auto Calibrate
31
3.
Press 
↓ and 
 together until ENTER SWITCH / UNLOCKED 
displays.
4.
Press 
↑ or ↓
 
until Label Length displays.
5.
Press + or 
 
until the value that matches the physical length of 
the installed media displays. See “Label Length” on page 42.
NOTE: Selecting the correct Label Length forces Auto Calibrate to 
increase media advancement for long labels (to detect 
actual gaps, notches, or marks) and decrease media 
advancement for short labels.
6.
Press 
↑ or ↓
 
until Gap/Mark Sensor displays.
7.
Press + or 
 
until the desired sensor type displays.
NOTE: If you are using smart labels, see “Gap Sensing for Smart 
8.
Press 
. An asterisk (*) displays next to the selected item.
9.
Press 
 
until Auto Calibrate / Run Calibrate displays.
10. Press 
. Media advances until it can accurately detect the label 
length indicators and then stops at the top-of-form position. The 
Sensed Distance value then displays for one second.
11. Auto Calibrate is successful when the Sensed Distance value 
correctly matches that of the installed media. For Gap sensing, 
the Sensed Distance value is the physical length of one label 
plus the length of one gap.
12. If GAP NOT DETECTED or PAPER OUT displays:
a.
Check the horizontal position of the media sensors 
(page 28).
b.
Make a Media Profile printout to verify that the sensors are 
performing properly (page 32).
c.
Press PAUSE and run Auto Calibrate again.
13. Press the PAUSE key to take the printer offline.
14. Press the FEED key several times. Each time you press FEED, 
the media should advance one label length and stop.
15. Once the Sensed Distance value and performance is 
confirmed, save it to the desired configuration menu as 
described on page 50 before powering off the printer.