CALIBRATE CTRL Submenus
139
CALIBRATE CTRL Submenus
Gap/Mark Sensor
The available options specify the sensor type needed for detecting the Top-of-
Form position on media with label length indicators (gaps, notches, holes, or 
black marks).
Disable. Select when using media with no label length indicators (no 
gaps, notches, holes, or black marks), or
 when you want the printer to 
ignore all existing label length indicators on the installed media.
NOTE: When you select Disable, the length of each label is based on the 
Label Length value entered in the MEDIA CONTROL menu or the 
value sent via host software.
Mark. Select when using media that has horizontal black marks located 
on the underside of the label liner or tag stock. The Top-of-Form position 
is the leading edge of the black mark.
Gap. Select
 when using media with a liner space between die-cut labels 
or when using tag stock with notches or holes as label length indicators 
on white background media. The Top-of-Form position is the leading 
edge of the die cut label (trailing edge of the gap, notch, or hole).
Advanced Gap. Select when using media that has liner gaps between 
die cut labels with black background. The Top-of-Form position is the 
leading edge of the die cut label (trailing edge of the gap, notch, or hole).
Advanced Notch. Select when using media with notches or holes that 
interrupt a black vertical line on the underside of the media. The Top-of-
Form position is the leading edge of the die cut label (trailing edge of the 
gap, notch, or hole).
The factory default is Disable.
Auto Calibrate
This feature is used to improve the sensitivity and reliability of the Media 
Sensors in detecting gaps, notches, holes, or black marks on the installed 
media, as well as a paper out condition.
NOTE: Prior to running Auto Calibrate you must enter the physical length of 
the installed media in the QUICK SETUP or MEDIA CONTROL 
menu. Selecting the correct Label Length forces Auto Calibrate to 
increase media advancement for long labels (to detect actual gaps, 
notches, or marks) and decrease advancement for short labels.
You can initiate Auto Calibrate from the TEST PRINT key, the CALIBRATE 
CTRL menu, or the DIAGNOSTIC menu. When “Auto Calibrate” displays on 
the LCD, press the 
 key. The printer advances media the distance needed to 
accurately detect the label length indicators, then stops at the Top-of-Form 
position, and momentarily displays the Sensed Distance. This process takes 
a few seconds to complete and results in changes to the values the printer 
uses for Gap/Mark Threshold, Paper Out Threshold, and Sensed Distance. 
These value changes take effect immediately within the current configuration 
menu.