Printronix SL5000r ユーザーズマニュアル

ページ / 396
254
Chapter
3
C/T PORT
C/T PORT
C/T PORT Submenus
Port Type
This item selects the desired active CTHI interface and appears only when 
the CTHI option is installed.
The factory default is Twinax.
Device Address
Allows you to set the device address from 0 through 6. The host directs data 
and commands on the twinax line to a specific device based on its unique 
device address. After the address has been changed, a Power On Reset 
(POR) status is sent to the host.
The factory default is 1.
Timeout
This item allows you to set the time that the printer, when it has not received 
data from its host, will begin to service all other host ports looking for data to 
print.
The range is from 5 to 60 seconds, and the factory default is 10 seconds.
Report Status
When a fault condition occurs in the printer, normally only the active port 
reports the fault to the host. With this item enabled, the port will report any 
fault even when it is not the current, active port.
The options are Disable (the factory default) and Enable.
C/T PORT 
1
Port Type
Twinax*
Coax
Disable
Device 
Address
Address 1*
Address 0-6
Timeout
10 sec.*
5-60 sec.
Report Status
Disable*
Enable
Notes:
* = Factory Default
1