Printronix SL5000r ユーザーズマニュアル

ページ / 396
RS-232
301
RS-232 And Optional RS-422 Serial Interfaces
NOTE: The RS-232 and RS-422 serial interface circuit characteristics are 
compatible with the Electronic Industry Association Specifications 
EIA
®
-232-E and EIA-422-B.
The RS-232 and RS-422 serial interfaces enable the printer to operate with bit 
serial devices that are compatible with an RS-232 controller. The input serial 
data transfer rate (in baud) is selectable from the printer's control panel. Baud 
rates of 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 are 
available.
NOTE: If you select a baud rate that is greater than 19200, you may need to 
use RS-422 to prevent data loss. You may also need to increase the 
Buffer Size in K parameter to improve performance.
The length of the data cable from the host computer to the printer must not 
exceed 50 feet (15 meters) for RS-232 or 4000 feet (1220 meters) for RS-422. 
(A copper conductor, twisted-pair telephone cable with a shunt capacitance of 
16 pF/foot [52.5 pF/meter] terminated in a 100 ohm resistive load must be 
used for the RS-422.)
RS-232
Received Data (RXD). Serial data stream to the printer.
Transmitted Data (TXD). Serial data stream from the printer for transmitting 
status and control information to the host. Subject to protocol selection.
Request To Send (RTS). Control signal from the printer. Subject to 
configuration.
Clear To Send (CTS). Status signal to the printer indicating the host is ready 
to receive data/status signals from the printer.
Data Set Ready (DSR). Status signal to the printer indicating the host is in a 
ready condition.
Data Carrier Detect (DCD). Status signal to the printer. The ON condition is 
required for the printer to receive data.
Data Terminal Ready (DTR). Control signal from the printer. Subject to 
configuration.
Table 14. RS-232 Serial Interface Connector (9 Pin) Assignments
Input Signals
Output Signals
Miscellaneous
Signal
Pin
Signal
Pin
Signal
Pin
Receive Data (RXD)
2
Transmit Status & Control 
Data (TXD)
3
Chassis/Signal Ground
5
Clear To Send (CTS)
8
Request To Send (RTS)
7
Data Set Ready (DSR)
6
Data Terminal Ready (DTR)
4
Data Carrier Detect (DCD)
1
RS-232 And Optional RS-422 Serial Interfaces