Printronix SL5000r ユーザーズマニュアル

ページ / 396
Positioning The Media Sensors
69
Sensing Media with Dark Background Labels with Gaps 
(Advanced Gap)
NOTE: Ribbon is not displayed in this illustration. The upper and lower 
sensors are designed to function with or without ribbon installed.
The upper sensor and lower sensor are used together to detect liner gaps 
between die cut labels that have a black or dark background on white or clear 
liner.
1.
Position the lower sensor directly under the center of the gap, and then 
place the upper sensor directly over the lower sensor.
2.
Check the position of the lower sensor by looking through the long, 
narrow opening in the media guard. Use the visible red light emitting from 
the lower sensor as a reference pointer.
3.
Use the sensor handle to manually position the sensor to the center of the 
gap in the media. Then use the handle on the upper sensor to position it 
directly above the lower sensor.
NOTE: When using ribbon, you may need to slide the ribbon to one side to 
adjust the upper sensor.
4.
Select “Advanced Gap” in the Gap/Mark Sensor submenu under the 
CALIBRATE CTRL menu. See “Sensing Different Media Types” on 
page 71.
5.
Upper Sensor 
Handle
Media Guard Opening
Visible Red Beam
Lower Sensor
Upper Sensor