Printronix p7010 ユーザーガイド

ページ / 342
P-Series Emulation (With LG)
145
P-Series Emulation (With LG)
Control Code 06
Control Code 06 defines the function of ASCII code hex 06 (ACK). You can 
select an alternate line spacing of 6, 8, or 10.3 LPI.
Control Code 08
Control Code 08 defines the function of ASCII code hex 08 (BS). You can 
define the code to output the following character:
Elongated (default).
Backspace.
Define CR Code
This option controls the action of the printer when it receives a Carriage 
Return code (hex 0D) from the host computer. If this feature is enabled, each 
time the printer receives a carriage return, it inserts an additional Line Feed 
code (hex 0A) into the data stream. Do not use this feature if the host 
computer sends Line feeds to the printer. 
CR = CR (default). Does not insert an extra line feed after each carriage 
return.
CR = CR + LF. Inserts an extra line feed after each carriage return. The 
next print position will be print position 1 of the next line.
Printer 
Protocol
Control Code 
06
Control Code 
08
Define CR 
Code
Auto LF
Overstrike
Define LF 
Code
P-Series
SFCC
EVFU Select
Alt. Set
80-9F
Character
Set
8.0 LPI*
 
10.3 LPI
 
6.0 LPI
Elongated*
 
Backspace
CR = CR*
 
CR = CR + LF
Disable*
 
Enable
Enable*
 
Disable
LF = CR + LF*
 
LF = LF
1*
 
(0-7F hex)
Enable*
 
Disable
Control Code*
 
Printable
* = Factory Default
P-Series
SFCC d
Command
Even dot plot*
 
Double high