Printronix P5000 ユーザーズマニュアル

ページ / 366
Dataproducts Parallel Interface Signals
283
Dataproducts Parallel Interface Signals
Data Lines 1 through 8. Provides eight standard or inverted levels 
from the host that specify character data, plot data, or a control code. 
Data Line 8 allows access to the extended ASCII character set. You 
can enable or disable this line via the Data Bit 8 parameter on the 
Dataproducts submenu (see page 243).
Data Strobe. Carries a high true pulse from the host when data is 
ready. The data strobe remains high until the Data Request line goes 
false. The active edge of the strobe signal can be configured as 
leading, middle (default), or trailing.
Paper Instruction (PI). Carries a DVFU signal from the host with the 
same timing and polarity as the data lines.
Ready. Carries a high true signal from the printer when AC power and 
DC voltages are present, paper is loaded properly, and the printer is not 
in a check condition.
Online. Carries a high true signal from the printer when the Ready Line 
is true and the ON LINE key on the control panel has been pressed. 
When the printer is in online mode, it may accept data from the host.
Demand/Data Request. Carries a high true signal from the printer 
when the printer is ready to accept character data from the host. This 
signal changes to false shortly after the leading edge of the data strobe 
signal.
Cable Verify. Two pins on the interface connector are jumpered 
together to allow the user to verify proper installation of the interface 
connector.
Buffer Clear. A high true level from the host to indicate the printer 
should perform a reboot.
Parity Error. Always carries a low false signal from the printer 
indicating there is no parity error.