RS-232 Serial Interface
263
RS-232 Serial Interface Signals
The RS-232 serial interface signals are defined below.
Receive Data (RxD) - Serial data stream to the printer.
Transmit Data (TxD) - Serial data stream from the printer for 
transmitting status and control information to the host. Subject to 
protocol selection.
Request To Send (RTS) - Control signal from the printer. Subject to 
configuration.
Clear To Send (CTS) - Status signal to the printer indicating the 
host is ready to receive data/status signals from the printer. When 
CTS is enabled, DSR and CTS must both be asserted for the 
printer to transmit flow control characters to the host.
Data Set Ready (DSR) - Status signal to the printer indicating the 
host is in a ready condition. DSR is ignored unless CTS or CD are 
enabled.
Carrier Detect (CD) - Status signal to the printer. The ON condition 
is required for the printer to receive data. Available as a 
configuration setup option.
 When CD is enabled, the host must 
assert both DSR and CD for the printer to 
accept data.
Data Terminal Ready (DTR) - Control signal from the printer to the 
host. When enabled, the host will activate the data channel. Subject 
to configuration.
RS-232 Serial Interface Configuration
The printer is configured for the RS-232 serial interface via the 
Serial Interface menu, as described on page 82. The following 
interface configuration parameters may be modified to meet 
specific application requirements:
Host Protocol
XON/XOFF
Baud Rate
9600
Data Bits (Word Length
8 Data Bits
Stop Bits
1 Bit