Printronix L5535 ユーザーズマニュアル

ページ / 290
Chapter 3
Host Interface Menu
76 
Centronics Parameters 
Data Bit 8
Enable. Allows access to the extended ASCII character set.
Disable. The printer interprets bit 8 of each incoming data 
character as a zero, regardless of its actual setting.
PI Ignored
The PI (Paper Instruction) signal is used to control vertical paper 
motion.
Enable. Ignores the PI signal and treats the data as characters 
or control codes
Disable. Causes the printer to interpret the eight data lines as 
VFU commands when the PI signal is true.
Ethernet
1
Serial
Host Interface
Data Bit 8
Enable*
Disable
Centronics
Dataproducts
PI Ignored
Data Polarity
Busy On 
Strobe 
Latch Data 
On
Prime Signal
TOF Action
Buffer Size 
In K
Disable*
Enable
Standard*
Inverted
Enable*
Disable
Leading *
Trailing
1
2
4
8
16
32
64*
128
Reset*
Do Nothing
Enable*
Disable
Auto 
Switching
IEEE 1284
Resp. 
Polarity
Standard*
Inverted
*
= Factory Default
1
= If installed