Dataproducts Parallel Interface Signals
235
Dataproducts Parallel Interface Signals
Data Lines 1 through 8. Provides eight standard or inverted levels from the 
host that specify character data, plot data, or a control code. Data Line 8 
allows access to the extended ASCII character set. You can enable or disable 
this line via the Data Bit 8 parameter on the Dataproducts submenu (see page 
page 79).
Data Strobe. Carries a high true pulse from the host when data is ready. The 
data strobe remains high until the Data Request line goes false. The active 
edge of the strobe signal can be configured as leading, middle (default), or 
trailing.
Paper Instruction (PI). Carries a DVFU signal from the host with the same 
timing and polarity as the data lines.
Ready. Carries a high true signal from the printer when AC power and DC 
voltages are present, paper is loaded properly, and the printer is not in a 
check condition.
Online. Carries a high true signal from the printer when the Ready Line is true 
and the ON LINE key on the control panel has been pressed. When the 
printer is in online mode, it may accept data from the host.
Demand/Data Request. Carries a high true signal from the printer when the 
printer is ready to accept character data from the host. This signal changes to 
false shortly after the leading edge of the data strobe signal.
Cable Verify. Two pins on the interface connector are jumpered together to 
allow the user to verify proper installation of the interface connector.
Buffer Clear. A high true level from the host to indicate the printer should 
perform a reboot.
Parity Error. Always carries a low false signal from the printer indicating there 
is no parity error.