Printronix P7000 ユーザーズマニュアル
IEEE 1284 Parallel (Bidirectional) Submenu
75
IEEE 1284 Parallel (Bidirectional) Submenu
The IEEE 1284 interface is faster and more versatile than Centronics and
supports bidirectional communication. Configuration of this interface is
controlled from the host. Refer to “IEEE 1284 Parallel Interface” on page 238
more details about the available modes (Compatibility, Nibble, and Byte).
supports bidirectional communication. Configuration of this interface is
controlled from the host. Refer to “IEEE 1284 Parallel Interface” on page 238
more details about the available modes (Compatibility, Nibble, and Byte).
Prime Signal
•
Enable (default). The parallel port will perform a warm start (reboot) if the
host asserts the prime signal.
host asserts the prime signal.
•
Disable. The parallel port will not perform a warm start (reboot) if the host
asserts the prime signal.
asserts the prime signal.
TOF Action
•
Reset (default). A form feed is performed before a warm start when the
prime signal is asserted from the host. This setting is used only if the
prime signal parameter is enabled.
prime signal is asserted from the host. This setting is used only if the
prime signal parameter is enabled.
•
Do Nothing. Nothing occurs before a warm start when the prime signal is
asserted from the host.
asserted from the host.
Buffer Size in K
This option configures the amount of memory allocated for the IEEE 1284
parallel port buffer. You can specify between 1 and 16 Kbytes, in 1-Kbyte
increments.
parallel port buffer. You can specify between 1 and 16 Kbytes, in 1-Kbyte
increments.
Auto Trickle
Auto Trickle is used to prevent a host computer from timing out because the
parallel interface was busy for too long. When Auto Trickle is enabled and the
printer's buffers are almost full, the printer will begin to trickle data in (at the
rate set in the Trickle Time menu) until the buffers start to empty.
parallel interface was busy for too long. When Auto Trickle is enabled and the
printer's buffers are almost full, the printer will begin to trickle data in (at the
rate set in the Trickle Time menu) until the buffers start to empty.
IEEE 1284
(from page 72)
Prime
Signal
TOF
Action
Buffer Size
in K
Enable*
Disable
Disable
Reset*
Do Nothing
Do Nothing
16*
1-16
1-16
* = Factory Default
Auto
Trickle
Disable*
Enable
Enable
Trickle
Time
1/4 sec*
1/2 sec
1 sec
2 sec
4 sec
8 sec
16 sec
Off
1/2 sec
1 sec
2 sec
4 sec
8 sec
16 sec
Off
Offline
Process
Disable*
Enable
Enable