Printronix P7000 ユーザーズマニュアル

ページ / 210
 110
Chapter
4
Printer MGMT
Printer MGMT
PNE Port
This menu selects which port the printer expects PNE to connect to, via 
Ethernet or Serial. The factory default is Ethernet.
Mgmt Protocol
Since PXML and UCP management protocols share the same Ethernet Port, 
only one can be active at a time. This menu selects the active Management 
Protocol Interface, either PXML or UCP. The factory default is UCP.
PNE Port Number
This menu selects the port number the printer expects the PNE to connect 
through. The factory default is 3001 and the range is from 1023 to 65535.
PNE Port Timeout
If the PNE has not communicated to the printer within a timeout period, the 
PNE session closes. The factory default is 100 seconds. The range is from 1 
to 255 seconds.
Status Port Numb
This menu selects the port number the printer sends the emulation status. 
The factory default is 3001 and the range is from 1023 to 65535.
Mgmt Port Number
This menu selects the port number the printer expects the PXML or UCP to 
connect through. The factory default is 3007 and the range is from 1023 to 
65535.
Printer MGMT
(from page 50)
PNE Port
UCP*
PXML
3001*
1023 - 65535
100 Seconds*
1-255 Seconds
* = Factory Default
1
 Not available if PNE Port number is set at Serial.
Mgmt 
Protocol
PNE Port 
Number 
1
PNE Port 
Timeout 
1
3002*
1023 - 65535
Status Port 
Numb
3007*
1023 - 65535
Mgmt Port 
Number
Ethernet*
Disable
Serial