Printronix SL5000r 参照ガイド

ページ / 394
SERIAL PORT Submenus
247
Data Protocol
You can select one of the following serial interface protocols to meet the host 
interface requirements.
XON / XOFF (the default). The printer controls the flow of communication 
from the host by turning the transmission on and off. In some situations, 
such as when the buffer is full or the timing of signals is too slow or too 
fast, the printer will tell the host to stop transmission by sending an XOFF 
character. An XOFF character is sent when the number of empty bytes in 
the buffer is less than or equal to 25 percent of the buffer size. If the host 
keeps sending data after an XOFF is sent, the printer firmware will 
continue to send an XOFF for every 16 characters received. When 
cleared, the printer will resume receiving data (XON). The data does not 
have any End of Text codes; XON / XOFF is a non-block protocol.
ETX / ACK. End of Text / Acknowledge. The host controls the flow of 
communication to the printer by sending a block of data and ending the 
block with an End of Text (ETX) signal. When the printer receives the ETX 
signal, it will acknowledge the ETX, thereby acknowledging it has 
received the entire block of data.
ACK / NAK. ACK means acknowledge; the device acknowledges it has 
accepted a transmission. NAK means negative acknowledge; the device 
did not receive the transmission.
Series1 1 Char. The printer controls the flow of communication from the 
host by turning the transmission on and off using response characters 
sent to the host. If the number of valid bytes in the buffer reaches 75 
percent of the buffer size, the online or offline and buffer full response 
character is sent. If the buffer is completely full, an online or offline buffer 
full response is sent every time a character is sent from the host. 
Whenever the printer state changes to online or offline, the appropriate 
response character is sent. If the idle response option is enabled, the 
printer will send a response character every two seconds while the 
number of valid bytes in the buffer is less than 75 percent of the buffer 
size. If a poll character is received (configurable from the Poll Character 
xx Hex option on the front panel from hex 0 through FF), the printer will 
send a response character n milliseconds later (configurable from the Poll 
Character 
xx MS on the front panel from 0 through 30). This n 
milliseconds is called the poll delay. The poll character will be removed 
from the input data stream and will not be processed. This may cause 
problems with the transmission of binary data (e.g., control codes, bit 
image, etc.). If a poll delay is started due to the receipt of a poll character 
and another poll character is received, the second poll character has no 
effect and is removed from the input data stream. If a transition (from 
buffer full to empty or online to offline) occurs during a poll delay, the new 
printer state will be sent at the end of the poll delay.