IEEE 1284 Parallel Interface
The IEEE 1284 supports three operating modes, which are determined by 
negotiation between the printer and the host.
Compatibility Mode
This mode provides compatibility with Centronics-like host I/O (see Table 11)
Data is transferred from the host to the printer in 8-bit bytes over the data 
lines.
Table 12. Centronix Parallel Interface Signals
Signals
Purpose
Data Lines 1 through 8
Provide eight standard or inverted levels from 
the host that specify character data, plot data, 
or a control code. Data Line 8 allows access to 
the extended ASCII character set. You may 
enable or disable this line via the Data Bit 8 
parameter on the Centronics Parallel submenu.
Data Strobe
Carries a low true, 100 ns minimum pulse from 
the host that clocks data into the printer.
Acknowledge
A low true pulse from the printer indicating the 
character or function code has been received 
and the printer is ready for the next data 
transfer.
Online
A high true level from the printer to indicate the 
printer is ready for data transfer and the PAUSE 
key on the control panel has been activated. 
When the printer is in online mode, it may 
accept data from the host.
Paper Empty (PE)
A high true level from the printer to indicate the 
printer is in a paper empty or paper jam fault.
Busy
A high true level from the printer to indicate the 
printer cannot receive data.
Prime
A high true level from the host to indicate the 
printer should perform a warm start (printer is 
reset to the power-up configuration values).
Paper Instruction (PI)
Carries a VFU signal from the host with the 
same timing and polarity as the data line.
Fault
A low true level from the printer indicates a 
printer fault.